FEBCO Products

  • Sale!1 "Reduced Pressure Zone Assy-Small Diameter 1 “Reduced Pressure Zone Assy-Small Diameter

    $324.97 $211.45

    1 “Reduced Pressure Zone Assy-Small Diameter

    The 1 “Reduced Pressure Zone Assy-Small Diameter, model 860 by FEBCO, is used in health-hazard applications. It is designed to protect drinking water supplies from dangerous cross-connections in accordance with national plumbing codes and water authority requirements for non-potable service applications such as irrigation, fireline, or industrial processing. The 1 “Reduced Pressure Zone Assy-Small Diameter compliances include ANSI/AWWA Conformance (C511), and Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California.

     

    Brochure

    Install Sheet

    Install Sheet (Relief Valve Assy)

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!1 1/2" Pressure Vacuum Breaker Assembly-765 1 1/2″ Pressure Vacuum Breaker Assembly-765

    $477.02 $264.75

    1 1/2″ Pressure Vacuum Breaker Assembly, for Health Hazard and Non-Health Hazard Backsiphonage

    The 1 1/2″ Pressure Vacuum Breaker Assembly, model 765 by FEBCO, is designed to provide protection against back siphonage of toxic or non-toxic liquids. They feature a durable bronze body and a check valve and air opening port in one assembly. Maximum Working Pressure: 150 psi (10.3 bar). The FEBCO 1 1/2″ Pressure Vacuum Breaker Assembly is used to protect against health hazard and non-health hazard backsiphonage conditions in industrial plants, cooling towers, laboratories, laundries, swimming pools, and lawn sprinkler systems.

    Install Instructions

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!2" Reduced Pressure Principle Assy 1 1/2″ Reduced Pressure Principle Assy

    $693.08 $381.19

    1 1/2″ Reduced Pressure Principle Assy

    The 1 1/2″ Reduced Pressure Principle Assy, model 825Y by FEBCO, is used to protect against high hazard (toxic) fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. The reduced pressure zone assembly consists of two independently operating, spring loaded, “Y” pattern check valves and one hydraulically dependent differential relief valve. It is used in irrigation systems, boiler feed, water lines and other installations requiring maximum protection. It has an internal relief valve pressure sensing passages, and has simple service procedures. All serviceable parts are in line. The1 1/2″ Reduced Pressure Principle Assy has low head loss, and replaceable seat rings on all sizes.

    In a flow condition the check valves are open with the pressure between the checks, called the zone, being maintained at least 5.0 psi lower than the inlet pressure and the relief valve is maintained closed. Should abnormal conditions arise under no flow or reversal of flow, the differential relief valve will open and discharge to maintain the zone at least 2psi lower than the supply. When normal flow resumes, the zone’s differential pressure will resume and the relief valve will close.

     

    Brochure

    Install Sheet

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!1 1/2" Small Footprint Reduced Pressure Zone Assy 1 1/2″ Small Footprint Reduced Pressure Zone Assy

    $864.60 $475.53

    1 1/2″ Small Footprint Reduced Pressure Zone Assy

    The 1 1/2″ Small Footprint Reduced Pressure Zone Assy, (Small Footprint “N-Shape” Design), model 825YA by FEBCO, is used to protect against high hazard (toxic) fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. It also used in irrigation systems, boiler feed, water lines, and other installations requiring maximum protection. The 1 1/2″ Small Footprint Reduced Pressure Zone Assy  features a bronze body and threaded ball valve shutoffs. Maximum Working Pressure: 175 psi. Mainline valve body and caps including relief valve body and cover are bronze. Check valve moving members shall be center stem guided. Relief valve has a removable seat ring. Check valve and relief valve components are constructed so they may be serviced without removing the valve body from the line. All seat discs are reversible.

    Brochure

    Install Instructions

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!1" Pressure Vacuum Breaker Assembly, 765 1″ Pressure Vacuum Breaker Assembly-765

    $145.00 $59.75

    1″ Pressure Vacuum Breaker Assembly, for Health Hazard and Non-Health Hazard Backsiphonage

    The 1″ Pressure Vacuum Breaker Assembly, model 765 by FEBCO, is designed to provide protection against back siphonage of toxic or non-toxic liquids. The vacuum breaker assembly has a single spring loaded check valve, which closes tightly when water flow through the assembly drops to zero, and a single air relief valve that opens to break the siphon when pressure drops to 1 psi against back siphonage of toxic or non-toxic liquids. It feature a durable bronze body and a check valve and air opening port in one assembly. Maximum Working Pressure: 150 psi (10.3 bar). The 1″ Pressure Vacuum Breaker Assembly is used to protect against health hazard and non-health hazard backsiphonage conditions in industrial plants, cooling towers, laboratories, laundries, swimming pools, and lawn sprinkler systems.

    Install Instructions

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!2" Reduced Pressure Principle Assy 1″ Reduced Pressure Principle Assy

    $365.04 $200.77
    Out of Stock

    1″ Reduced Pressure Principle Assy

    The 1″ Reduced Pressure Principle Assy, model 825Y. by FEBCO, is used to protect against high hazard (toxic) fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. The reduced pressure zone assembly consists of two independently operating, spring loaded, “Y” pattern check valves and one hydraulically dependent differential relief valve. It is used in irrigation systems, boiler feed, water lines and other installations requiring maximum protection. It has an internal relief valve pressure sensing passages, and has simple service procedures. All serviceable parts are in line. The 1″ Backflow Prevention Assy-825Y has low head loss, and replaceable seat rings on all sizes.

    In a flow condition the check valves are open with the pressure between the checks, called the zone, being maintained at least 5.0 psi lower than the inlet pressure and the relief valve is maintained closed. Should abnormal conditions arise under no flow or reversal of flow, the differential relief valve will open and discharge to maintain the zone at least 2psi lower than the supply. When normal flow resumes, the zone’s differential pressure will resume and the relief valve will close.

     

    Brochure

    Install Sheet

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!1" Small Footprint Reduced Pressure Zone Assy 1″ Small Footprint Reduced Pressure Zone Assy

    $477.04 $262.37

    1″ Small Footprint Reduced Pressure Zone Assy

    The 1″ Small Footprint Reduced Pressure Zone Assy, (Small Footprint “N-Shape” Design), model 825YA by FEBCO, is used to protect against high hazard (toxic) fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. It also used in irrigation systems, boiler feed, water lines, and other installations requiring maximum protection. The 1″ Small Footprint Reduced Pressure Zone Assy features a bronze body and threaded ball valve shutoffs. Maximum Working Pressure: 175 psi. Mainline valve body and caps including relief valve body and cover are bronze. Check valve moving members shall be center stem guided. Relief valve has a removable seat ring. Check valve and relief valve components are constructed so they may be serviced without removing the valve body from the line. All seat discs are reversible.

    Brochure

    Install Instructions

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!1" Pressure Vacuum Breaker Assembly, 765 2″ Pressure Vacuum Breaker Assembly-765

    $529.56 $291.15
    Out of Stock

    2″ Pressure Vacuum Breaker Assembly, for Health Hazard and Non-Health Hazard Backsiphonage

    The 2″ Pressure Vacuum Breaker Assembly, model 765 by FEBCO, is designed to provide protection  The vacuum breaker assembly has a single spring loaded check valve, which closes tightly when water flow through the assembly drops to zero, and a single air relief valve that opens to break the siphon when pressure drops to 1 psi against back siphonage of toxic or non-toxic liquids. They feature a durable bronze body and a check valve and air opening port in one assembly. Maximum Working Pressure: 150 psi (10.3 bar). The FEBCO 2″ Pressure Vacuum Breaker Assembly is used to protect against health hazard and non-health hazard backsiphonage conditions in industrial plants, cooling towers, laboratories, laundries, swimming pools, and lawn sprinkler systems.

    Install Instructions

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!2" Reduced Pressure Principle Assy 2″ Reduced Pressure Principle Assy

    $734.64 $404.05

    2″ Reduced Pressure Principle Assy

    The 2″ Backflow Prevention Assy, model 825Y by FEBCO, is used to protect against high hazard (toxic) fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. The reduced pressure zone assembly consists of two independently operating, spring loaded, “Y” pattern check valves and one hydraulically dependent differential relief valve. It is used in irrigation systems, boiler feed, water lines and other installations requiring maximum protection. It has an internal relief valve pressure sensing passages, and has simple service procedures. All serviceable parts are in line. The 2″ Backflow Prevention Assy-825Y has low head loss, and replaceable seat rings on all sizes.

    In a flow condition the check valves are open with the pressure between the checks, called the zone, being maintained at least 5.0 psi lower than the inlet pressure and the relief valve is maintained closed. Should abnormal conditions arise under no flow or reversal of flow, the differential relief valve will open and discharge to maintain the zone at least 2psi lower than the supply. When normal flow resumes, the zone’s differential pressure will resume and the relief valve will close.

     

    Brochure

    Install Sheet

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!2" Small Footprint Reduced Pressure Zone Assy 2″ Small Footprint Reduced Pressure Zone Assy

    $935.64 $561.38
    Out of Stock

    2″ Small Footprint Reduced Pressure Zone Assy

    The 2″ Small Footprint Reduced Pressure Zone Assy, (Small Footprint “N-Shape” Design), model 825YA by FEBCO, is used to protect against high hazard (toxic) fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. It also used in irrigation systems, boiler feed, water lines, and other installations requiring maximum protection. The  2″ Small Footprint Reduced Pressure Zone Assy features a bronze body and threaded ball valve shutoffs. Maximum Working Pressure: 175 psi. Mainline valve body and caps including relief valve body and cover are bronze. Check valve moving members shall be center stem guided. Relief valve has a removable seat ring. Check valve and relief valve components are constructed so they may be serviced without removing the valve body from the line. All seat discs are reversible.

    Brochure

    Install Instructions

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!Febco 3/4" Pressure Vacuum Breaker Assembly-765 3/4″ Pressure Vacuum Breaker Assembly-765

    $135.24 $55.00

    3/4″ Pressure Vacuum Breaker Assembly, for Health Hazard and Non-Health Hazard Backsiphonage

    The 3/4″ Pressure Vacuum Breaker Assembly, model 765 by FEBCO, is designed to provide protection against back siphonage of toxic or non-toxic liquids. The vacuum breaker assembly has a single spring loaded check valve, which closes tightly when water flow through the assembly drops to zero, and a single air relief valve that opens to break the siphon when pressure drops to 1 psi against back siphonage of toxic or non-toxic liquids. It feature a durable bronze body and a check valve and air opening port in one assembly. Maximum Working Pressure: 150 psi (10.3 bar). The FEBCO 3/4″ Pressure Vacuum Breaker Assembly is used to protect against health hazard and non-health hazard backsiphonage conditions in industrial plants, cooling towers, laboratories, laundries, swimming pools, and lawn sprinkler systems.

    Install Instructions

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!2" Reduced Pressure Principle Assy 3/4″ Reduced Pressure Principle Assy

    $346.50 $190.60
    Out of Stock

    3/4″ Reduced Pressure Principle Assy

    The 3/4″ Reduced Pressure Principle Assy, model 825Y by FEBCO, is used to protect against high hazard (toxic) fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. The reduced pressure zone assembly consists of two independently operating, spring loaded, “Y” pattern check valves and one hydraulically dependent differential relief valve. It is used in irrigation systems, boiler feed, water lines and other installations requiring maximum protection. It has an internal relief valve pressure sensing passages, and has simple service procedures. All serviceable parts are in line. The 3/4″ Reduced Pressure Principle Assy has low head loss, and replaceable seat rings on all sizes.

    In a flow condition the check valves are open with the pressure between the checks, called the zone, being maintained at least 5.0 psi lower than the inlet pressure and the relief valve is maintained closed. Should abnormal conditions arise under no flow or reversal of flow, the differential relief valve will open and discharge to maintain the zone at least 2psi lower than the supply. When normal flow resumes, the zone’s differential pressure will resume and the relief valve will close.

     

    Brochure

    Install Sheet

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!3/4" Small Footprint Reduced Pressure Zone Assy 3/4″ Small Footprint Reduced Pressure Zone Assy

    $448.08 $246.44

    3/4″ Small Footprint Reduced Pressure Zone Assy

    The 3/4″ Small Footprint Reduced Pressure Zone Assy, (Small Footprint “N-Shape” Design), model 825YA by FEBCO, is used to protect against high hazard (toxic) fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. It also used in irrigation systems, boiler feed, water lines, and other installations requiring maximum protection. The  3/4″ Small Footprint Reduced Pressure Zone Assy features a bronze body and threaded ball valve shutoffs. Maximum Working Pressure: 175 psi. Mainline valve body and caps including relief valve body and cover are bronze. Check valve moving members shall be center stem guided. Relief valve has a removable seat ring. Check valve and relief valve components are constructed so they may be serviced without removing the valve body from the line. All seat discs are reversible.

    Brochure

    Install Instructions

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!Double Check Valve Assembly-1 inch Double Check Valve Assembly-1 inch

    $192.50 $128.01

    Double Check Valve Assembly-1 inch

    The Double Check Valve Assembly-1 inch, model 850 by FEBCO, is composed of two single, independently acting check valves. The unit also has two tightly closing, resilient seated, shutoff valves located at each end of the device and four test cocks for the testing of the check valves. The Double Check Valve Assembly-1 inch is designed for non-health hazard applications. Approvals and standards include:

    • ANSI/AWWA C511 Conformance

    • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California

     

    Brochure

    Install Sheet

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!Double Check Valve Assembly-2 inch Double Check Valve Assembly-2 inch

    $461.50 $299.98

    Double Check Valve Assembly-2 inch

    The Double Check Valve Assembly-2 inch, model 850 by FEBCO, is composed of two single, independently acting check valves. The unit also has two tightly closing, resilient seated, shutoff valves located at each end of the device and four test cocks for the testing of the check valves. The Double Check Valve Assembly-2 inch is designed for non-health hazard applications. Approvals and standards include:

    • ANSI/AWWA C511 Conformance

    • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California

     

    Brochure

    Install Sheet

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...
  • Sale!Double Check Valve Assembly-3/4 inch Double Check Valve Assembly-3/4 inch

    $171.00 $111.15

    Double Check Valve Assembly-3/4 inch

    The Double Check Valve Assembly-3/4 inch, model 850 by FEBCO, is composed of two single, independently acting check valves. The unit also has two tightly closing, resilient seated, shutoff valves located at each end of the device and four test cocks for the testing of the check valves. The Double Check Valve Assembly-3/4 inch is designed for non-health hazard applications. Approvals and standards include:

    • ANSI/AWWA C511 Conformance

    • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California

     

    Brochure

    Install Sheet

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

     

    More ...
  • Sale!Double Check Valve Assembly-850 1-1/2 inch Double Check Valve Assembly-850 1-1/2 inch

    $387.50 $251.88

    Double Check Valve Assembly-850 1-1/2 inch

    The Double Check Valve Assembly-850 1-1/2 inch, model 850 by FEBCO, is composed of two single, independently acting check valves. The unit also has two tightly closing, resilient seated, shutoff valves located at each end of the device and four test cocks for the testing of the check valves. The Double Check Valve Assembly-850 1-1/2 inch is designed for non-health hazard applications. Approvals and standards include:

    • ANSI/AWWA C511 Conformance

    • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California

     

    Brochure

    Install Sheet

    Maintenance Manual

    Spec Sheet

    FEBCO Warranty

    More ...